Publication:
Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study

Publisher DOI
10.1186/s12903-023-02857-8
Date
2023-04-07

Type
Article
Authors
Fouda, Ahmed Mahmoud
Bourauel, Christoph
Journal Title
Journal ISSN
Volume Title
Publisher
Springer Nature
Publisher DOI
Source
https://bmcoralhealth.biomedcentral.com/articles/10.1186/s12903-023-02857-8
Full item page

Research Projects
Organizational Units
Journal Issue
Abstract
Background: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. Methods: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 Î¼m to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. Results: All groups’ internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. Conclusion: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration.
Description
Keywords
Endocrowns - Lithium disilicates, Peek, Internal fit, Marginal gap
Citation
Nagi, N., Fouda, A.M. & Bourauel, C. Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials - an in vitro study. BMC Oral Health 23, 207 (2023). https://doi.org/10.1186/s12903-023-02857-8
Journal Title
BMC Oral Health
Journal Title
Journal Title
Volume
23
Issue
1
Volume
Collections
Creative Commons License

© 2023 by the authors. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.